Skip to main content

Film cooling: case of double rows of staggered jets.

Author
Abstract
:

An experimental investigation of film cooling of a wall in a case of double rows of staggered hot jets (65 degrees C) in an ambient air flow. The wall is heated at a temperature value between the one of the jets and the one of the main flow. Experiments have been carried out for different injection rates, the main flow velocity is maintained at 32 m/s. Association of the measures of temperature profiles by cold wire and the measures of wall temperature by infrared thermography allows us to describe the behaviour of the flows and to propose the best injection which assures a good cooling of the plate.

Year of Publication
:
2001
Journal
:
Annals of the New York Academy of Sciences
Volume
:
934
Number of Pages
:
337-44
ISSN Number
:
0077-8923
URL
:
https://onlinelibrary.wiley.com/resolve/openurl?genre=article&sid=nlm:pubmed&issn=0077-8923&date=2001&volume=934&spage=337
DOI
:
10.1111/j.1749-6632.2001.tb05868.x
Short Title
:
Ann N Y Acad Sci